Descargar Imprimir esta página

Invacare Aquatec Pure Bidet Manual Del Usuario página 5

Ocultar thumbs Ver también para Aquatec Pure Bidet:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
3.
Put the washers G on both packing nuts.
4. Set in place the brackets E on the catch plate F.
5. Fasten the catch plate with the fixation bolts D through
the brackets in both packing nuts.
6.
Screw the PVC flexible hose H clockwise on the inlet
adapter I of the shower toilet.
7. Slide the shower toilet to the catch plate F installed.
CAUTION!
– Make sure that the grooves underneath the
shower toilet are precisely guided in the
recesses of the catch plate.
8.
Screw the PVC flexible hose K clockwise on the T-valve
L.
Assembling the Remote Control
1.
A
Attach the remote control holder with double stick tape
A on the wall in a suitable location.
2.
Remove battery cover B from remote control.
3. Insert batteries C. Ensure correct polarity.
4. Close battery cover of remote control.
5. Place remote control into its holder D.
1590625-G
4.2 Assembling Concealed Cistern (optional)
Installing water flow over angle valve
1. Connect angle valve and bidet with the PVC Flexible
hose.
2. Turn the water tap on.
NOTICE!
– Check the connection for leaks and re-fit if
necessary.
Installing water flow over flush-mounted housing
1. Remove the push plate from the flush-mounted housing.
2. Remove the rear cover plate to obtain a direct
perspective on the connection.
3. Turn the water tap off.
4. Remove connecting sleeve D and replace by T-piece E.
5. Connect T-piece with PVC Flexible hose C.
6. Connect PVC Flexible hose with tube A using nut B.
7. Connect tube A with pure bidet.
8. Turn the water tap on.
NOTICE!
– Check the connection for leaks and re-fit
if necessary.
9. Cut-out inner cover plate F, mounting plate G and
push plate H according to the figure above taking into
account the indicated dimensions [mm].
10. Re-attach the inner cover plate and the mounting plate
inside the flush-mounted housing.
11. Close flush-mounted housing with the push plate.
Following parts are needed for the assembly of the
flush-mounted water flow:
Tube A
Nut B
Available at your specialised provider.
4.3 Trial Operation
Leakage Test
A
5

Publicidad

loading