Sonesse 40 WireFree RTS Li-ion
3.6. ADJUSTING THE SPEED
͉
͉
Orange LED blinks slowly in this mode.
1) Move the motorised product away from the end limits. Press
and hold the UP, MY and DOWN buttons simultaneously, until
the motorised product briefly moves Up and Down once. The
motorised product will move UP and Down automatically in
10 second cycles and green LED blinks 5 times to validate
entering in speed adjustment mode.
2) To increase the speed, press and hold the UP button until the
motorised product briefly moves Up and Down. and green
LED blinks 5 times. Repeat as needed.
͉
͉
Maximum speed is reached when the motorised product
moves briefly 3 times in one direction and 3 times in the other
direction. Red LED blinks 3 times and 3 times intermittently.
3) To decrease the speed, press and hold the DOWN button until the motorised product briefly
moves Up and Down. Repeat as needed.
͉
͉
Minimum speed is reached when the motorised product moves briefly 3 times in one direction and 3
times in the other direction.
4) To confirm the new speed, press and hold the MY button until the motorised product briefly
moves Up and Down and green LED blinks 5 times.
3.7. TIPS AND ADVICE ON OPERATION
Observations
The motorised product
does not operate.
The motorised
products stops before
its end limit
Copyright
©
2019 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
Possible causes
The control point battery is low.
LED doesn't light when any but-
ton of a paired control point is
pressed.
Drive battery is low and requires
charge. Red LED blinks 5 times
when any button of a paired
control point is pressed.
RTS is deactivated. LED doesn't
light when any button of a paired
control point is pressed.
Thermal protection of the drive is
on (Red LED blinks slowly).
The drive has detected an
obstacle (solid Red LED).
1
2
3
Solutions
Change control point battery as
required.
Plug in the charger.
Press drive PROG. button.
Wait for the drive to cool down (Red
LED will stop blinking when drive is
ready to use.
Move the motorised product in the
other direction.
EN
10
10
s
s
4