Operation Introduction for Control Panel
Name of control panel
Swing indicator
Fan button
Fan speed indicator
NOTICE
● After putting through the power,the air conditioner will give out a sound. After that,you can operate the air conditioner by the control
panel.
● Under ON status, after each pressing of the button on control panel, the air conditioner wiil give out a sound. Meanwhile, coresponding
indicator on control panel will be bright.
● Under OFF status, dual-8 nixie tube on control panel won't display.Under ON status, dual-8 nixie tube on control panel will display set
temperature under cooling mode and Heating mode IPE-1221GH Model only, while it won't display under other modes.
Operation of control panel
1
ON/OFF button
Pressing this button can turn on or turn off
the air conditioner.
2
+ / - button
Under cooling or heating mode, press "+" or
"-" button to increase or decrease set
temperature by 1°C(°F). Set temperature
range is 16°C(61°F)~30°C(86°F) . Under
auto, dry or fan mode, this button is invalid.
3
Fan button
Press this button and the fan speed will circulate as:
low speed
auto fan
4
Mode button
Press this button and the mode will circulate as:
Cool
Heat
(IPE-1221GH Model only)
Cool: Under this mode, cool mode indicator is
bright. Dual-8 nixie tube displays set tempera-
ture.Temperature setting range is
16°C(61°F)~30°C(86°F).
Dry: Under this mode,dry mode indicator is
bright. Dual-8 nixie tube won't display.
Fan: Under this mode, the air conditioner only
+ / - button
Dual-8 nixie tube
Swing button
medium speed
high speed
Dry
Fan
Timer indicator
Cool mode indicator
Mode button
Timer button
(IPE-1221GH Model only)
blow fan. Fan mode indicator is bright.
Dual-8nixie tube won't display.
Heat (IPE-1221GH Model only) : Under this
mode, heating mode indicator is bright. Dual-8
nixie tube displays set temperature.Tempera-
ture setting range is 16°C(61°F)~30°C(86°F).
5
Timer button
Press this button and the mode will circulate
according to below sequence:
Press timer button to enter into timer setting
mode. Under this mode, press "+" or "- "
button to adjust the timer setting.Timer setting
will increase or decrease 0.5 hour by pressing
" + " or " - " button within 10 hours, while timer
setting will increase or decrease 1 hour by
pressing"+" or " - " button beyond 10 hours.
After timer setting is finished, the unit will
display temperature if there's no operation for
5s. lf timer function is started up, the upper
indicator will keep the display status. Others, it
won't be displayed. Under timer mode, press
timer button again to cancel timer mode.
6
Swing
Press this button, horizontal louver of air
conditioner will swing up&down automatically.
Single press it to switchover between on and off.
4
Dry mode indicator
ON/OFF button
Fan mode indicator
Heat mode indicator
EN
Op