Follower
If follower foam appears to be damaged or
does not wipe sides of reservoir effectively
service may be necessary († fig. , page
and fig. IPB , page ; or fig. IPB ,
page ).
Disconnect electric supply from pump.
Remove bolts (), eyebolts () and lock
washers () which attach cover () to
reservoir assembly ().
Lift pump (), vent valve () and drum
cover () out of reservoir ().
Remove cable assembly () from fol-
lower assembly ().
Remove follower assembly from reser-
voir assembly.
Wipe off excess grease from follower
assembly.
Loosen and remove nuts () on top of
follower assembly.
Remove weighted follower plate () and
follower foam ().
Replace with new foam.
Remove and save spacers () from
inside of foam before discarding foam.
Reverse above procedure to re-assemble
making sure long bolts () are staggered
with small ones ().
NOTE
Do not bend housing tube during
removal of pump, vent valve and drum
cover.
Mechanical low level
indicator
Indicator seal () may be damaged if indi-
cator pin appears to drop prematurely or
water is noticeable on top of follower,
(† fig. , page and fig. IPB ,
page ; or fig. IPB , page ).
Remove bolts (), eyebolts () and lock
washers () which attach cover () to
reservoir assembly ().
Inspect reservoir gasket seal () for dam-
age. If damage is apparent, replace gasket.
Remove entire pump, vent valve and fol-
lower assembly from reservoir.
Remove retaining ring () from indicator
rod assembly ().
Hold indicator plug () with wrench while
removing indicator nut ().
Remove and replace o-ring ().
Reassemble in reverse of above
procedure.
Safety unloader valve
Safety unloader valve () († fig. IPB ,
page or fig. IPB , page ) is not
serviceable. Replace if malfunction is
apparent. Upon reassembly, tighten to
ft-lbf (13.5 Nm).
Safety unloader valve () is set to open at
to psi (258 to 293 bar) lubricant
pressure. If pressure switch fails to operate
and shut off hydraulic supply to pump, safety
unloader will open at approximately
psi (275 bar) to relieve lubricant
supply line pressure (safety unloader is
preset and not adjustable).
Automatic
mechanical shut-off
Refer to manual for automatic
mechanical shut-off.
Bare pump assembly
Refer to manual for bare pump
assembly ().