Problem
Water flows on the ground.
The temperature in the appliance
is too low.
The temperature in the appliance
is too high.
The temperature in the refrigera-
tor is too high.
Replacing the bulb
If you want to replace the bulb, do these steps:
1. Break the circuit of the appliance.
2. Unscrew the lamp cover securing screw.
3. Unhook the moving part by pressing it as shown in
the figure.
4. Replace the bulb with one of the same power (the
maximum power is shown on the light bulb cover)
5. Fix the lamp cover in place.
6. Screw the lamp cover securing screw.
7. Reconnect the appliance.
8. Open the door and check if the light comes on.
Technical data
Dimension
26
Possible cause
Products prevent that water flows into
the water collector.
The melting water outlet does not flow
in the evaporative tray above the com-
pressor.
The temperature regulator is not set
correctly.
The temperature regulator is not set
correctly.
The door is not closed correctly.
The product temperature is too high.
Many products are stored at the same
time.
There is no cold air circulation in the
appliance.
Height
Width
Depth
Make sure that products do not touch
the rear plate.
Attach the melting water outlet to the
evaporative tray.
Set a higher temperature.
Set a lower temperature.
Refer to "Closing the door".
Let the product temperature decrease to
room temperature before storage.
Store less products at the same time.
Make sure that there is cold air circula-
tion in the appliance.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Con-
tact the Service Center.
850 mm
550 mm
612 mm