2.2
INSTALLATION
2.2.1
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH
The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Instructions for the "Installation of electrical equipment"
- Prescriptions by the Electrical Supply Company
- Hygienic regulations.
2.2.2
INSTALLATION PLACE
- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2cu.m/hr l kW T.C.
(Thermal Capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.2.3
POSITIONING
- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
2.2.4
ASSEMBLY OF TOP EQUIPMENT ON COUNTERBASIS
Unscrew and take away the two frontal foot (P) from the
equipment, which is to be located on the counter, place it
on this so that the 2 back foot (N) fit in the corner of the
base as represented in the picture.
Place the equipment completely and fix it screwing the 2
frontal foot (P) through out the base's holes for the fixing
of it.
GB
- 14 -