Descargar Imprimir esta página

Speedaire C283-B Manual De Instrucciones De Operación Y Partes página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

Speedaire
Operating Instructions & Parts Manual
Speedaire
Two-Stage Air Compressors
Installation (Continued)
Simplex models 4XA59, 4XA60,
4XA61, 4XA62, 1WD54, 1WD55,
1WD57, 1WD58, 1WD61, 1WD63
E
thru 1WD65, and 13G706 thru
N
13G709 have a factory mounted
and wired magnetic starter. The
G
starter provides motor overload
L
protection. See Figure 1-1 for
I
wiring diagram. Connections exist
S
between the pressure switch and
H
the starter.
305CAS546-B
(Ref. Drawing)
For Service and Warranty, Call: 1-888-303-1344.
4XA59 thru 4XA62, 4XA67, 4XA68, 1WD46, 1WD48, 1WD54, 1WD55,
1WD57, 1WD58, 1WD61, 1WD63 thru 1WD65, 13G706 thru 13G709
5 & 7.5 HP
®
Duplex models 4XA67, 4XA68,
1WD46, and 1WD48 have factory
mounted and wired magnetic
starters and alternator. The starters
provide motor overload protection.
See Figure 1-2, for wiring diagram.
must be such that when viewing
compressor from opposite
shaft end, rotation of shaft is
clockwise as shown by arrow on
guard. Wrong direction rotation
for any length of time will result
in damage to compressor.
Figure 1-1 Wiring Diagram
Grounding Instructions
This product should be connected to
a grounded, metallic, permanent wiring
system, or an equipment grounding
terminal or lead on the product.
Wiring
304CAS546-A
(Ref. Drawing)
6

Publicidad

loading