DAILY START-UP
1.
Check the oil level in the pump (see "Checking the Oil" in the maintenance
section).
2.
Make sure the main power disconnect switch is shut OFF.
Close the tank petcock (see E).
3.
4.
Turn ON the main power disconnect switch. Turn the pressure switch to the
AUTO position (see D). The pump will start filling the tank with air. When the
air pressure in the tank reaches the level preset at the factory, the pressure
switch will turn off the electric motor. As air is used and the pressure level in
the tank drops, the pressure switch will start the motor and the pump will
begin refilling the tank.
WARNING
⚠
prevent burns or other injuries, DO NOT touch the pump or transfer
tube while the pump is running. Allow it to cool before handling or
servicing. Keep children away from the compressor at all times.
NOTE: If the unit does not operate properly, SHUT DOWN IMMEDIATELY, and
contact a qualified service center.
SHUTDOWN
1.
Turn the pressure switch to the OFF position (see C).
2.
Shut OFF the main power disconnect switch.
3.
Reduce pressure in the tank through the outlet hose. You can also pull the
tank safety valve ring (see G) and keep it open to relieve pressure in the
tank.
WARNING
⚠
may cause eye injury. Wear safety goggles when opening petcock.
4.
Open the petcock (see F) to allow moisture to drain from the tank.
OPERATING INSTRUCTIONS
(Fig. 6)
High temperatures are generated by the pump. To
(Fig. 6)
Escaping air and moisture can propel debris that
14- ENG