3.5 Analog inputs (connector CN1)
The maximum voltage applicable to an analog input on RI1000 is 14V (adjustment range: 0-14V).
A different range for the voltage signal (e.g. adjustment range: 0-10V or 0-5V) can be set by programming analog inputs on control
panel.
CN1-13
Wire 9
CN1-5
Wire 10
CN1-14
Wire 11
CN1-6
Wire 12
24
ANALOG INPUT 1 (AI1): positive input (+)
ANALOG INPUT 1 (AI1): negative input (-)
The parameter managed by this analog input can be selected and programmed by control panel.
Default: welding current.
0V = minimum of selected parameter
14V = maximum of selected parameter
ANALOG INPUT 2 (AI2): positive input (+)
ANALOG INPUT 2 (AI2): negative input (-)
The parameter managed by this analog input can be selected and programmed by control panel.
Default: welding voltage.
0V = minimum of selected parameter
14V = maximum of selected parameter