5 CONNECTORS
5.1 Connector CN1/J1 (16-pole)
CN1-1
START ARC input
0V = arc OFF
24V = arc ON
CN1-2
WIRE EXTENSION input
0V = wire not extended
24V = wire extended
CN1-3
WIRE BACK input
0V = wire back inactive
24V = wire back active
CN1-4
AIR TEST input
0V = no air flow
24V = air flow
CN1-5
ANALOG input 1 (-)
CN1-6
ANALOG input 2 (-)
CN1-7
"WELDING TOOL READY"
output
0V = system in alarm status
24V = system ready for use
CN1-8
ARC ON output
0V = arc OFF
24V = arc ON
CN1-9
GAS TEST input
0V = test inactive
24V = test active
CN1-10
EMERGENCY ALARM input
0V = system in alarm status
24V = system operating
normally
CN1-13
ANALOG input 1 (+)
CN1-14
ANALOG input 2 (+)
CN1-15
PROGRAMMABLE DIGITAL
OUTPUT 1
0V = digital output inactive
24V = digital output active
CN1-16
5.2 Connector CN2/J2 (4-pole)
J1-1
Wire 1
J1-2
Wire 2
CN2-1
CN2-2
J1-3
Wire 3
CN2-3
CN2-4
J1-4
Wire 4
5.3 Connector CN12/J12 (2-pole)
J1-5
Wire 10
STANDARD DIGITAL inputs
J1-6
Wire 12
J1-7
Wire 13
CN12-1
J1-8
Wire 15
CN12-2
INVERTED DIGITAL inputs
J1-9
Wire 5
J1-10
Wire 8
CN12-1
CN12-2
J1-13
Wire 9
J1-14
Wire 11
J1-15
Wire 14
PROGRAMMABLE DIGITAL
OUTPUT 1
0V = digital output inactive
24V = digital output active
+24V
Ground (PE)
Ground
Ground
Not used
Ground
In short-circuit
J1-16
Wire 16
J2-1
Wire 20
J2-2
Yellow green
wire
J2-3
Wire 19
J2-4
Wire 18
J12-1
-
J12-2
J12-1
J12-2
27