3. Technical data
3.4 Model PGT23.100 / PGT23.160
Working pressure
- Steady
- Fluctuating
- Transient
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible temperatures
- Ambient
- Medium
Further technical data see data sheet PV 1.04
3.5 Model PGT43.100 / PGT43.160
Working pressure
- Steady
- Fluctuating
- Transient
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible temperatures
- Ambient
- Medium
Further technical data see data sheet PV 14.0
3.6 Model PGT43HP.100 / PGT43HP.160
Working pressure
- Steady
- Fluctuating
- Overload capability
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible temperatures
- Ambient
- Medium
Further technical data see data sheet PV 14.07
WIKA Operating Instructions intelliGAUGE family
Full scale range
0.9 x full scale range
1. x full scale range
max. ± 0.4 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP 54 per EN 60 59 / IEC 60 59
IP 65
filled/unfilled -40 ... +60 °C
maximum +100 °C
Full scale range
0.9 x full scale range
5 x full scale range, however max. 40 bar
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP 54 per EN 60 59 / IEC 60 59
IP 65
filled/unfilled -0 ... +60 °C
maximum +100 °C
Full scale range
0.9 x full scale range
40, 100 and 400 bar
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP 54 per EN 60 59 / IEC 60 59
IP 65
filled/unfilled -0 ... +60 °C
maximum +100 °C