Control Panel - Dirna bycool 950 Manual Del Usuario

Con mando a distancia
Ocultar thumbs Ver también para bycool 950:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

950
EN

Control Panel

temperature selector
15/27 ºC
59/80 ºF
Compressors
1.- On/off: Switching the unit On - Off and mode selection F4/ F0/ F1/ F2/ F6
2.- Temperature selector (15/ 27 ºC - 59/80º F) Remote control programmation,
Farenheit degrees and Air Speed: Ambient temperature control and blower speed
(between 1st and 5th speed) manual mode only.
3.- Display: Screen showing the function selected and the status of the equipment.
4.- Led On - Indicate the compressors functioning.
• On connection, the equipment checks the leds and 88-bd appears on the screen and turns off.
Special display messages
"Technical Control" Battery low (will emit bips during a brief period of time and the
:
kit will turn off)
Poor contact of the sensor recirculation wires or lead anti-recirculation broken
EO:
down.
Poor contact of the anti-ice sensor or lead anti-ice broken down.
E6:
Turning the Equipment On
To turn the 950 unit on, press the On/ Off key
Function (Automatic Function).
To change the function, hold down the On/ Off key
displayed, release the key on obtaining the desired function.
2
4
(please see failure Diagnosis)
:
. The unit will always start up on the
. The different functions will be
8
dirna
, s.a.
3
display