Residual gas: No smoking!
No open flames!
– Close the empty gas cylinder's
valve.
– Remove the high pressure
hose from the gas cylinder
and remove the clip-on adapt-
er, if present.
– Attach the high pressure hose
to the full gas cylinder and
apply the clip-on adapter, if
present.
– Open the full cylinder's valve.
– Press the hose-break safety de-
vice and the gas-flow monitor
(see "Taking into operation").
Anytime after making
changes, check the hose
connection to the cylinder valve
for leaks (see "Checking for
leaks in the high pressure area").
12
Exchanging hoses
Please use the included screw-
ing tool to attach and remove
the high pressure hoses. It will
help you generate the neces-
sary tightening torque and will
prevent damage to the screw
fittings, which may otherwise re-
sult from using an improper tool.
Residual gas: No smok-
ing! No open flames!
– Close the gas cylinder's valve.
– Remove the high pressure
hose from the gas cylinder
(or from the slip-on adapter)
and from the regulator inlet.
When performing a
hose change, please
ensure that the gasket pro-
vided with the hose (hose out-
let – regulator inlet) is correctly
installed and not damaged.
We recommend that the
gasket (part no. 50020-
76300) be replaced with every
hose change.
– Screw country-specific high-
pressure hose to SecuMotion
inlet and cylinder (or to
adapter).
– Open the gas cylinder's valve.
– Press the hose-break safety
device and, if necessary, the
gas-flow monitor (see "Taking
into operation").
Anytime after making changes,
check the hose connections to
the cylinder valve and to the inlet
of the SecuMotion gas-pressure
regulator for leaks (see "Check-
ing for leaks in the high pressure
area").