SQUARING PROCEDURE
1. Mark a reference (point x) on the floor that
is equidistant from each wall in the center
of a room.
2. Turn ON the laser and switch to the
"Unlocked" position. Ensure that laser is
in Perpendicular Level, Plumb Points, and
Horizontal Points mode (all lasers ON).
3. Using the down plumb point, align the
laser directly over the center of point (x)
on the floor.
4. With the laser in place, mark point (I) at
the intersection of the lines directly in front
of the laser on wall A. Without moving the
laser, also mark the center of the right
Horizontal point (II) on wall B.
5. Rotate the laser 90 degrees clockwise
around plumb point (x) and align the left
Horizontal dot with the previously marked
point I.
6. With the laser in position, mark point (III)
on wall B at the intersection of the
perpendicular lines directly in front of the
laser. Without moving the laser, mark point
(IV) on wall C using the right horizontal
point.
7. The deviation (d) between points II & III
should be no more than 3 mm at 10 m .
ENGLISH
8. Lastly, rotate the laser 180º clockwise
around plumb point (x) so that the right
horizontal point is aligned with the
previously marked point I. Without
moving the laser, using the left horizontal
point mark (V) on wall C.
9. The deviation (d) between points IV & V
should be no more than 3 mm at 10 m.
13