5.1 Models 3TSM ci, 4TSM2, 4TSM4, 4TSM6 and 4TSM8 ci
(With internal electronic controller)
For proper installation, it is necessary to use circuit breakers or direct current fuses between the solar panels
and the motor pump.
Before installing the motor pump or carrying out any maintenance, the DC circuit breaker or fuse must be
turned off.
Make the electrical connections according to the following table and electrical diagram. Make sure the
polarities are correctly connected.
For your safety and safety of the installation, make sure that all cables are correctly connected before
connecting the equipment.
46
Model
3TSM ci/8
3TSM ci/11
3TSM ci/13
3TSM ci/17
4TSM2-12 ci 1100W
4TSM6-11 ci 1500W
4TSM4-15 ci 2200W
4TSM6-14 ci 2200W
4TSM8-10 ci 2200W
Figure - Electrical installation diagram (internal controller)
EBARA BOMBAS AMÉRICA DO SUL LTDA.
3TSM ci/ce and 4TSM ci
Positive (+)
Negative (-)
Brown
Blue
Red
Black
Models