Descargar Imprimir esta página

Flex VCE 22 M MC Instrucciones De Funcionamiento Originales página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
VCE 22 M MC/VCE 22 M MC/VCE 26 H MC
4.2
Transport
Before transporting the machine, close all the
latches.
Close the inlet with the inlet cap.
Do not tilt the machine if there are liquids in the
dirt tank.
Do not use a crane hook to lift the machine.
4.3
Storage
CAUTION
Store the appliance in a dry place, protected
from rain and frost. The machine shall be
stored indoors only. Wet filters and the interior
part of the liquid container shall be dried be-
fore storage.
4.4
Recycling the machine
Make the old machine unusable.
1. Unplug the machine.
2. Cut the power cord.
3. Do not discard of electrical appliances with
household waste.
Equipment marked with the crossed-out
wheeled bin symbol indicates that used
electrical and electronic equipment should
not be discarded together with unseparated house-
hold waste. To avoid negative effects on human
health and the environment the equipment must be
collected separately at the designated collection
points.
Users of electrical and electronic household equip-
ment must use the municipal collection schemes.
Please note that commercially used electrical and
electronic equipment, shall not be disposed of via
municipal collection schemes. We will be pleased to
inform you about suitable disposal options.
5
Maintenance
5.1
Regular servicing and inspection
Regular servicing and inspection of your machine
must be carried out by suitably qualified personnel in
accordance with relevant legislation and regulations.
In particular, electrical tests for earth continuity, in-
sulation resistance, and condition of the flexible cord
should be checked frequently.
In the event of any defect, the machine MUST be
withdrawn from service, completely checked and
repaired by an authorized service technician.
At least once a year, a FLEX technician or an in-
structed person must perform a technical inspection
including filters, air tightness and control mecha-
nisms.
For appliances in Dust Class H the machine filtration
efficiency should be either tested at least annually or
the essential filter is replaced by a new one.
OEL=Occupational Exposure Limit,
1)
Original instruction
5.2
Remove the plug from the socket before performing
maintenance. Before using the machine make sure
that the frequency and voltage shown on the rating
plate correspond with the mains voltage.
The machine is designed for continuous heavy work.
Depending on the number of running hours – the
dust filter should be renewed. Keep the machine
clean with a dry cloth, and a small amount of spray
polish.
During maintenance and cleaning, handle the ma-
chine in such a manner that there is no danger for
maintenance staff or other persons.
In the maintenance area
Use filtered compulsory ventilation
Wear protective clothing
Clean the maintenance area so that no harmful
substances get into the surroundings.
Before removing the machine from the area contami-
nated with harmful substances:
Clean the outside of the machine, wipe it clean or
pack the machine in well sealed packaging and
avoid spreading deposited harmful dust.
During maintenance and repair work all contami-
nated parts that could not be cleaned satisfactorily
must be:
Packed in well sealed bags
Disposed of in a manner that complies with valid
regulations for such waste removal.
For details of after sales service contact your
dealer or FLEX service representative responsible
for your country. See reverse of this document.
Optional accessories / Option depending on model
*)
Maintenance
CAUTION
23

Publicidad

loading

Este manual también es adecuado para:

Vce 22 m mc vVce 26 h mc