Descargar Imprimir esta página

SICK WL24-2 Instrucciones De Uso página 11

Ocultar thumbs Ver también para WL24-2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
7
Commissioning
8008783.1DMA/2022-07-12 | SICK
Subject to change without notice
Test input
Test input: the WL24-2B / -V sensors feature a test input ("TI" or "Test" on the connec‐
tion diagram
[see „WL24-2Bxxx, WL24-2Vxxx", page 8
be used to switch the sender off and, therefore, check that the sensor is functioning
correctly: if female cable connectors with LED indicators are used, you have to ensure
that the TI is assigned accordingly.
There must be no object between the sensor and reflector; activate the test input (see
the connection diagram
[see „WL24-2Bxxx, WL24-2Vxxx", page 8
TE at 0V at PNP) (PNP: TE → M; NPN: TE → L+). The send LED is shut down or the
detection of an object is simulated. Use the following table to check the function. If
the switching output fails to behave in accordance with the following table, check the
application conditions. See section Fault diagnosis.
Table 7: Test
1
Alignment
Align the sensor with a suitable reflector. Select the position so that the red emitted light
beam hits the center of the reflector. The sensor must have a clear view of the reflector
with no object in the path of the beam [see
optical openings of the sensor and reflector are completely clear.
Figure 3: Alignment
OPERATING INSTRUCTIONS
and
see table
7]), which can
and
see table
Test
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
figure 3
and
figure
4]. You must ensure that the
Figure 4: Alignment 2
O P E R A T I N G I N S T R U C T I O N S | WL24-2
7],
en
11

Publicidad

loading

Este manual también es adecuado para:

W24-2