Type SPC D/PID positioner
4
Assembly
NOTE!
Only for positioners and process controllers without premounted process valve.
DANGER!
Risk of injury due to high pressure in the system/device.
► Before working on the system or device, switch off the pressure and vent/drain the lines.
Risk of injury from electric shock!
► Before intervening in the device or the system, switch off the power supply and secure it against being switched on again!
► Observe the applicable accident prevention and safety regulations for electrical devices!
WARNING!
Risk of injury due to improper assembly!
► Assembly may only be carried out by authorized specialist personnel using suitable tools!
Risk of injury due to unintentional switching on of the system and uncontrolled restart!
► Secure the system against unintentional operation.
► After assembly, make sure the system is restarted under controlled conditions.
4.1
Assembly
4.1.1
Construction
1
2
3
4
5
16
No.
Designation
1
Control air connection 2
2
Control air connection 2
6
3
Fixing screws max. 1.5 Nm
4
Control air connection top
5
Control air connection bottom
6
Type SPC Positioner
7
Actuator
7
8
Valve
8
Operating Instructions