Type SPC positioner
3.4
Technical Data
Specification
General data
Operating temperature
Storage temperature
Protection rating
Deployment height
Housing material
Sealing material
Valve spindle stroke range
Putting into operation/Initialization
Pneumatic data
Control medium
Dust content
Water content
Oil content
Temperature range of control medium
Pressure range of control medium
Air capacity control valve
Fluidic connection
Electrical data (without bus activation)
Protection class
Ports
Temperature rating connection cable
Supply voltage
Power consumption
Input resistance for setpoint signal
Analog position feedback
Digital input
For UL approved components, only circuits of limited power according to „NEC Class 2" may be used.
14
-10 to +55 °C
-20 to +65 °C
IP 65 / IP67 nach EN 60529 (evaluated by the manufacturer)
up to 2000 m above sea level
relative humidity max. 95 % at 50 °C (not condensating)
External: PPS, PC, VA, PP-FR
Internal: PA 6; ABS
NBR/EPDM
3 - 45 mm
Automatically through X.TUNE function
(automatic adjustment of the positioner)
Neutral gases, air
Quality class as per ISO 8573-1
Quality class 7,
max. particle size 40 μm,
max. particle density 10 mg/m³
Quality class 3,
max. pressure dew point -20 °C or
min. 10 °C below the lowest
Operating temperature
Quality class X, max. 25 mg/m³
0 to +50 °C
3 - 7 bar
Type SPC: 7 l
/min (for aeration and ventilation)
N
(Q
-value according to definition at pressure drop from 7 to 6 bar absolute)
Nn
Type SPC*: 130 l
/min (for aeration and ventilation)
N
Threaded joint G 1/8
III as per DIN EN 61140 (VDE 0140-1)
1x circular connector (M12 x 1, 8-pin)
min. 75 °C
24 V DC ± 25% - max. residual ripple 10%
< 5 W
4 to 20 mA
Input resistance 75 Ω
•
Resolution 12 bit
•
Max. current
10 mA
Burden (load)
0 - 560 Ω (for current output 4 - 20 mA)
PNP
0 - 5 V = log "0", 10 - 30 V = log "1"
Inverted input correspondingly inverted (input current < 6 mA)
Operating Instructions