5.6 STOVE LEVELLING
The stove must be levelled, with the help of a spirit
level, by regulating the adjustable feet (if included) fig.
5.10).
A B = Spirit Level
5.7 CONNECTION TO UTILITIES
5.7.1 Electrical connection
It is sufficient to connect the stove to the electrical
system using the supplied plug.
The electrical connection (plug) must be easily
accessible even after installing the stove.
If the power cord is damaged, it must be replaced
by the technical assistance service or by a qualified
technician in order to prevent any risk.
5.7.1.1 Earthing
The system must be earthed and equipped with a
differential switch in accordance with legislation in force
(fig. 5.11).
Make sure the power cord does not come into contact
with hot parts.
The flue gas exhaust pipe must have its own earth
connection.
5.8 OPTIMISATION OF COMBUSTION
Best combustion depends on a variety of factors (type
of installation, operating and maintenance conditions,
type of pellets, etc...)
Upon the first ignition, the stove's combustion can be
optimised.
Generally speaking, if there is a lot of residue in the
burn pot at the end of combustion, it is recommended
to adjust the combustion configuration (increasing the
value) until the most suitable solution is found.
See sections 9.17- 9.18 - 9.19.
5.9 VENTILATION
The stove is equipped with ventilation.
The air pushed by the fans keeps the appliance at
a low enough temperature, thus avoiding excessive
stress on the materials of which it is composed.
Do not close the hot air outlet vents with any objects
or the stove will overheat!
The stove is not suitable for cooking food.
ATTENTION: Do not cover the air vents.
14
02/2023 - EN
Product images are purely indicative
Fig. 5.10
Fig. 5.10