MAINTENANCE
(by an authorised technical assistance centre)
6.1 MAINTENANCE
Maintenance operations must be performed by an authorised
technical assistance centre.
Before performing any maintenance operation, take the following
precautions:
-
Make sure that all the parts of the stove are cold.
-
Make sure that the ashes are completely extinguished.
-
Use personal protective equipment provided for by Directive
89/391/EEC.
-
Make sure that the general line switch is turned off .
-
Make sure that the power supply cannot be accidentally
reactivated. Remove the plug from the wall socket.
-
Always use appropriate equipment for maintenance.
-
Once the maintenance or the repair operations are completed,
before re-commissioning the stove, install again all the
protections and restart all the safety devices.
6.1.1 FLUE SYSTEM MAINTENANCE
To be performed at least once a year, or every 40 tons of burned
pellets.
If there are horizontal sections, it is necessary to check and
remove any ash and soot deposits before they block the passage
of the fl ue gases.
In the event of failure or inadequate cleaning, the stove may
have functional problems such as:
-
bad combustion
-
glass blackening
-
blockage of the burn pot with accumulation of ash and pellets
-
risk of fl ue catching fi re.
6.1.2 STOVE MAINTENANCE
It must be carried out at least once a year, or each time the stove
indicates that maintenance is required.
During the maintenance operation, the technician must:
-
clean the fl ue gas passage area thoroughly and completely;
-
check the condition of all the seals and make sure they work
properly;
-
check the condition of all internal components and make sure
they are clean;
-
make sure the fl ue gas outlet connection is sealed and clean;
-
remove any deposits of pellet residues in the tank;
-
make sure that the stove is working properly;
-
reset any warnings or alarms
-
for easy access to the fl ue gas box (A), simply remove the lid
(B) by adjusting the two screws (C) (Fig. 6.1.2).
6.1.3 GASKET REPLACEMENT
If the gaskets of the fi re door, tank or fl ue gas chamber become
worn, they must be replaced by an authorised technician in order
to guarantee the proper operation of the stove.