Before Returning For Repairs; Specifications - Schumacher SC1309 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
The display shows
"bAD / bAt / F01 ".
The display shows
"bAD / bAt / F02".
The display shows
"bAD / bAt / F05".

14. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.

15. SPECIFICATIONS

Input .................................120V AC @ 60Hz, 10A max. continuous, 48A max. intermittent
Output .......................................................................................... 2A continuous @ 6V DC
POSSIBLE CAUSE
The battery voltage is still below
10V (for a 12V battery) or 5V
(for a 6V battery) after 2 hours of
charging.
Desulfation was unsuccessful,
after 10 hours.
Lack of progress is detected after
12 hours in Maintain mode.
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
6<>2A @ 12V DC intermittent (60 sec. @ 6A; 120 sec. @ 2A)
200A @ 12V DC intermittent (5 sec. max. on, 180 sec. min. off)
The battery may be defective.
Make sure there are no loads on
the battery. If there are, remove
them. If there are none, have the
battery checked or replaced.
The battery may be defective.
Have battery checked or replaced.
The battery won't hold a charge.
May be caused by a drain on the
battery or the battery could be bad.
Make sure there are no loads on
the battery. If there are remove
them. If there are none, have the
battery checked or replaced.
• 11 •
SOLUTION
40A continuous @ 6/12V DC

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido