Final Checks; User Instruction - Erreka CICLON CL210 Manual Del Instalador

Accionador electromecánico para puertas batientes
Ocultar thumbs Ver también para CICLON CL210:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5

FINAL CHECKS

Connections and checks
F
< 400N in spaces between 50 mm and 500 mm
d
F
< 1400N in > 500 mm spaces
d
Programming the operations
In dual leaf facilities without brake or encoder,
the following should be taken into account when
programming the operations:
when programming closing for leaf 2, once the leaf
reaches the closing stopper wait for a time equal to
the lapse between leaves before pressing ST1 to
finish programming. This ensures that during the
closing operation, leaf 2 remains at the closing
stopper during the lapse, until leaf 1 closes
completely.

User instruction

1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the user manual.
2 Signpost the door, showing that it opens
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
1 Install an electrolock to lock the door in closing
position. This is always necessary for the CL210,
CL250 models and all other models whenever leaf
length is over 1.8 m.
2 Carry out the installation and the connections for all
the elements of the facility, in line with the control
board instructions.
3 Check that the mechanism is correctly regulated.
The torque regulator of the control board must
be adjusted in a manner which respects the
values indicated in standard EN 12453:2000, as
shown
measurements must be made in line with the
method described in standard EN 12445:2000.
4 Check the operation of all the installation elements,
especially the protection systems and the manual
operation unlocking system.
indicate
that
See the electrolock instructions.
in
the
attached
CICLÓN Electromechanical Operator
INSTALLATION
chart.
The
53

Publicidad

Tabla de contenido
loading

Tabla de contenido