MAINTENANCE AND TROUBLESHOOTING

1

MAINTENANCE

Before
carrying
operation, disconnect the device from the
power supply.
1 Frequently check the installation in order to discover
any imbalance or sign of deterioration or wear. Do not
use the device if any repair or adjustment is necessary.
2

TROUBLESHOOTING

Problem
The operator does not make any
movement when the opening or
closing controls are activated
By activating the opening or
closing controls, the operator is
enabled but the door does not
move
The door moves in an irregular
manner
The door cannot completely close
(or open)
3

SCRAP

The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. This
will avoid possible accidents and damage to
adjacent facilities.
4

SPARE PARTS

If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
54
Installation Manual
out
any
maintenance
Cause
Absence of system power supply
voltage
Electrical installation defective
Defective control board or control
devices
Door obstructed or blocked
The angle formed by the two
sections of the articulated arm is
too big or too small
D o o r p a r t i a l l y o b s t r u c t e d o r
blocked
The photocell detects an obstacle
The resistance of the door has
increased when closing (or when
opening)
The force of the operator during
closing (or opening) is too low
The mechanical stoppers of the
d o o r o r t h e o p e r a t o r a r e
maladjusted
2 Clean and lubricate the joints of the door, so as not
to increase the effort of the operator.
3 Check that the controls and photocells, as well as
their installation, have not suffered any damage
from the weather or external agents.
Solution
Restore the power supply
Check that the installation does not
present any short-circuits or cut-off
points
C h e c k t h e s e e l e m e n t s i n t h e i r
respective manuals
Unblock, adjust and lubricate the door
joints
Carry out installation again, respecting
the levels indicated in the "Fig. 6
Example of assembly position for
operator with articulated arm"
Unblock, adjust and lubricate the door
joints
Remove the obstacle and try again
Check the moving parts of the door
and remove the resistance
Increase the closing or opening force
using the control board programming.
Adjust the stoppers
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying of the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not controlled, as this will cause
environmental damage.
Use only original spare parts. See the figure
"Content and spare parts" on page 43.

Publicidad

Tabla de contenido
loading

Tabla de contenido