Open/close adjustment URCM92180(M) and URCM92300(M) (fig 7c)
Knob A (orange) adjusts the open/close (number of turns) of movement A, and
knob B (green) adjusts the open/close of movement B.
Act as follows to adjust open/close.
1 The electrical connections must be completed (fig. 6).
2 Uncouple the shutter from its tube (T) so the tube remains attached to the
adapter (crown (9) and drive wheel (11) in figure 2).
3 Press the up/down buttons and check that the tube moves in the correct
direction.
4 Press the down button until the operator stops automatically.
5 Keeping the down button pressed, adjust the knob for the down limit
switch in direction (–) until the tube (T) is in a position to fasten the blind.
6 Fasten the blind in its tube (T).
7 Press the up button until the operator stops automatically.
8 Keeping the up button pressed, adjust the knob for the up stopper until the
shutter is in the maximum opening position required.
5

MAINTENANCE AND USE

Open/close must be adjusted before using the
operator and the manual operator crank.

Manual operation

URCM59120(M) (fig. 5a): position the crank (not supplied) in
the coupling (5a) and turn it in the required direction.
URCM92180(M) and URCM92300(M) (fig. 5b): position the
crank (not supplied) in the coupling (5b) and turn it in the
required direction.
Manual operation is for emergencies only.
Do not operate the crank while electric power is
being applied to the operator.
The product should be dismantled by qualified personnel at
the end of its working life.
This product consists of a variety of materials, some of which
can be recycled and others which must be disposed of. Users
must be aware of the different recycling and disposal systems
envisaged in local regulations.
12
Troubleshooting
• The operator stops working following prolonged use: the
thermal protection device has cut off the operator in order
to prevent excess heating; the operator will work again
once it has cooled down.
• The open/close is incorrectly adjusted: check that the crown
(9) rotates along with the tube (T) and with the limit switch
ring (10).
WARNINGS FOR SCRAP
Some parts of this product may contain contaminating or
hazardous substances which, if released, could harm the
environment and human health.
Discarding this device along with household
waste is forbidden. Carry out selective sorting
according to local regulations.