Descargar Imprimir esta página

Metabo HPT DV 18DGL Manual Del Usuario página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

Pilot lamp
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the Table 3, and batteries that have
become hot should be cooled for a while before being
recharged.
Table 3 Recharging ranges of batteries
Rechargeable
Temperatures at which the battery
batteries
BSL1815S
BSL1815
BSL1830C
Battery
Fig. 4
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 1 second. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
can be recharged
32°F – 122°F
(0°C – 50°C)
3. Charging
When the battery is connected to the battery charger,
charging will commence and the pilot lamp will light in
red. (See Table 2)
NOTE
If the pilot lamp fl ikers in red, pull out the plug from
the receptacle and check if the battery is properly
mounted.
When the battery is fully charged, the pilot lamp
will blink in red slowly. (At 1-second intervals) (See
Table 2)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the charger or
the rechargeable battery.
Table 2
(3) Regarding recharging time (At 68°F (20°C))
Depending on the combination of the charger and
batteries, the recharging time will become as shown
in Table 4.
Table 4 Charging time (At 68°F (20°C))
Charger
Battery
BSL1815S
BSL1815
BSL1830C
English
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger
UC18YKSL
Approx. 35 min.
Approx. 40 min.
Approx. 90 min.
11

Publicidad

loading