Connection To The Evaluation Unit - Balluff BTL7-S5 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL7-S5 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
8
Technical data (continued)
8.7

Connection to the evaluation unit

The maximum sampling frequency f
current value is available with each sampling, can be found
in the following graphic:
f
in Hz
A,max
Fig. 8-1:
Maximum sampling rate depending on the nominal length (for position output).
The maximum SSI clock frequency f
the cable length
1)
:
f
in kHz
Clk,max
Fig. 8-2:
Maximum SSI clock frequency depending on the cable length
1) For long cables: Required cable cross-section ≥ 0,6 mm
www.balluff.com
, at which a new
A,max
is dependent on
Clk,max
2
or ≤ AWG19
The minimum sampling frequency f
Nominal length in mm
Cable length in m
Ignition protection
"nA" and "tb"
is 62,5 Hz.
A,min
(1) = 1 magnet
(2) = 2 magnets
(only BTL7-S510(B-)...)
english
21

Publicidad

Tabla de contenido
loading

Tabla de contenido