Installation
The following installation steps refer to the pictures at the beginning of this manual.
The unit can be mounted on the ceiling or on the wall. For mounting, the unit must have a minimum
distance of 1.8m to the floor and 1.5m to other walls.
Components:
No.
Part Name
1
Expansion Bolt M6*70
2
Upper L Bracket
3
Washer
4
Spring Washer
5
Screw Nut M6
6
Screw M6*16
Included accessory:
Accessory Name
Upper L Bracket
Lower L Bracket
Expansion Bolt M6*70
Screw M6*16
Remote Control
Allen Key
Screw M6*8
Washer
Spring Washer
Screw Nut M6
1. Drill two holes on the wall or ceiling. The distance between the holes depends on the model (Fig. A):
Heat Blade 1800 black design: L= 858mm
Heat Blade 2400 black design: L= 1138mm
Heat Blade 3200 black design: L= 1513mm
2. Insert the expansion bolts (#1) into the holes. Use a spanner to twist the screw nuts (#5) on the
expansion bolts clockwise until the expansion bolts are securely located in the holes. Unscrew the screw
nuts and put them aside together with the washers (#3) and spring washers (#4) for further use.
3. Put the upper L brackets (#2) onto the ceiling or the wall. To do so, lead the holes of the upper L brackets
through the expansion bolts and fix them with the washers (#3), spring washers (#4) and screw nuts
(#5) that were set aside in point 3.
4. Put the lower L brackets (#7) on the back of the unit. Fix them with two M6*8 screws (#10) each.
5. Fix the upper L brackets (#2) to the lower L brackets (#7) with the two M6*16 screws (#6). In case of
wall mounting, make sure that the conrol panel is on the left side.
6. The unit can be adjusted within a downwards angle of 30°. To do so, loosen the M6*16 screws (#6),
adjust your desired angle, then tighten the screws again (Fig. B)
Operation
Operating voltage:
Heat Blade 1800 black design: 220-240V~, 50Hz, 1500-1800W
o
Heat Blade 2400 black design: 220-240V~, 50Hz, 2000-2400W
o
Heat Blade 3200 black design: 220-240V~, 50Hz, 2700-3200W
o
Please connect the unit to the power supply.
For turning on, press the on/off switch at the left side of the unit. „-" flashes on the display and the unit
is in standby mode.
Press the mode button on the control panel or on the remote control (excl. 2 x AAA batteries) to switch
on the heating and to select the heating level. Each model has three heating levels:
Heat Blade 1800 black design: 550W/1150W/1800W
o
Heat Blade 2400 black design: 750W/1000W/2400W
o
Heat Blade 3200 black design: 1000W/2000W/3200W
o
Note: It may take time for the device to reach the set heating level. The device gets very hot during
operation. Please touch the device only after cooling down.
To set a timer for turning off, press the button „+/-" on the control panel or remote control. The timer can
be selected between 0 and 9 hours (0 means the timer is off). When the timer is switched on, the display
shows the heating level 1, 2 or 3 for 10 seconds and the timer for 5 seconds alternately.
No.
Part Name
7
Lower L Bracket
8
Main Switch
9
Control Panel
10
Screw M6*8
11
Allen Key
12
Remote Control
Qty
2
2
2
2
1
1
4
2
2
2

Publicidad