A1 TECHNICAL DATA
Model EQPLB
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power (*) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Nominal current (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature 35°C;
chilled water temperature 7°C; temperature differential at evaporator 5 K;
fouling factor equal to 0.35x10
(***) Sound pressure level in dB(A) referring to a 10 m distance from the
unit, in free field and directionality factor equal to Q=2. The noise data
refers to the units without the electric pump.
(****) Sound power level in dB(A) on the basis of measurements taken in
accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards. The
noise data refers to the units without the electric pump
kW
kW
dB(A)
dB(A)
dB(A)
n°
n°
n° x kW 6x1.8 6x1.8 6x1.8 8x1.8 8x1.8 8x1.8 10x1.8
m³/h
Type
m³/h
kPa
kPa
kPa
kPa
l
kW
m³/h / kPa 80,8/65 88/74 98,7/70 110,9/74 121,4/86 134,1/81 142,9/82 149,9/60 164,1/74 177,3/84 186,7/78 196/86
kW
m³/h / kPa
Kg
Kg
kW
kW
V-ph-Hz
V-ph-Hz
A
A
A
A
A
mm
mm
mm
Ø
Ø
Kg
-4
m
2
K/W.
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
361
391
436
498
541
2,93 2,88 2,85
3
2,94 2,81 2,98 2,95 2,98 2,88 2,85 2,84
4,75 4,74 4,72 4,83 4,79 4,72 4,77 4,76 4,84 4,76 4,75 4,72
359,8 389,6 434,6 496,3 538,9 587,9 637,7 666,5 732,4 784,0 827,1 861,8
2,9
2,84 2,81 2,96
2,9
4,11
4,1
4,09 4,16 4,15 4,09 4,14 4,06 4,19 4,12 4,11 4,08
62
63
64
64
64
94
95
96
96
96
89
90
91
91
91
4/4
4/4
4/4
5/5
6/6
2
2
2
2
2
119500 119500 119500 159500 159500 159500 199000 199000 238000 238000 238000 238000
Plates/Shell and tube (STE accessory)
62,1 67,2
75
85,6
93
38
43
40
44
50
100
87
114
98
77
139
125
173
160
140
91
76
100
89
65
129
114
160
151
129
700
700
700 1000 1000 1000 1000 1000 1000 1000 1000 1000
470
512
574
645
706
93
99
113
127
139
8/5
8,5/6 9,7/7 10,9/8 12/9 13/9 14,1/9 15/15
35
35
38
47
47
20,8 20,8 20,8
26
31,2 31,2 31,2 31,2 36,4 41,6 41,6 41,6
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
123,0 136,0 153,0 166,0 184,0 210,0 215,0 227,0 247,0 273,0 291,0 305,0
4,0/5,5 4,0/5,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5
230 – 1 – 50 / 24 – 1 – 50
202
223
251
273
302
268
308
326
366
398
494
504
549
588
624
379
397
430
469
509
7,6/10,5 7,6/10,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 14,5/21 14,5/21 14,5/21 14,5/21
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260
3740 3740 3740 4840 4840 4840 5940 5940 7150 7150 7150 7150
DN80
DN80
DN80
DN100
DN100
VIC
VIC
VIC
VIC
VIC
2" VIC 2" VIC 2" VIC 2" VIC 2" VIC
2130 2140 2200 2670 2860 2890 3205 3230 3870
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature produced equivalent to
40/45°C (RC100) 50/60°C (DS).
(■) Absorbed power/absorbed current without electric pump.
The peak current refers to the unit's most heavy duty operating
conditions.
(°) Data calculated in accordance with EN 14511:2013 under nominal
conditions.
The refrigerant charge values are indicative. Refer to the serial number
plate.
230
590
640
669
735
787
2,77 2,93 2,90 2,93 2,84 2,81 2,80
64
64,5 64,5 64,5 64,5 65,0 66,0
96
97
97
97
97
91
92
92,5 92,5 92,5 93,0 94,0
6/6
6/6
6/6
7/6
8/6
2
2
2
2
2
10x1,8 12x1,8 12x1,8 12x1,8 12x1,8
101,4 110 115,0 126,4 135,3 142,7 148,7
46
48
50
48
53
85
73
61
92
80
114
102
86
134
123
72
57
44
85
72
100
86
69
128
115
780
831
872
954 1031 1091 1140
151
164
175
203
206
17,5/28 17,7/31 18,7/35 19,1/40
51
61
61
86
86
7,5/11 7,5/11 7,5/11 7,5/11
400 – 3 – 50
345
353
373
406
448
458
480
494
556
610
684
702
717
780
808
549
582
598
661
702
DN100
DN100
DN100
DN125
DN125
VIC
VIC
VIC
VIC
VIC
2"1/2
2"1/2
2"1/2
3" VIC 3" VIC 3" VIC 3" VIC
VIC
VIC
VIC
4020 4100 4120
830
865
98
99
8/6
8/6
2
2
48
52
78
69
122
112
70
60
113
103
218
222
92
92
478
501
631
653
856
877
736
758
DN150
DN150
VIC
VIC