Descargar Imprimir esta página

Ingersoll Rand P1.5IU-A9 Manual Del Usuario página 4

Ocultar thumbs Ver también para P1.5IU-A9:

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
„ INSTALLING THE AIR INLET FILTER
Do not operate without air inlet filter.
Install the air inlet filters at the inlet connections at the bare pump. If
heavy duty filtration is required, contact your dealer for information.
„ INSTALLING DISCHARGE PIPING
If it is necessary to install air discharge piping or condensate
discharge piping, adhere to the following general guidelines.
Contact your dealer for more information.
If an aftercooler, check valve, block valve, or any other
restriction is added to the compressor discharge, install a
properly-sized ASME approved safety/relief valve between the
compressor discharge and the restriction.
If you will be using All Season Select synthetic compressor
lubricant, all downstream piping material and system
components must be compatible. Refer to the following
material compatibility list. If there are incompatible materials
present in your system, or if there are materials not included
in the list, contact your dealer.
Suitable:
Viton®, Teflon®, Epoxy (Glass Filled), Oil Resistant Alkyd, Fluorosilicone,
Fluorocarbon, Polysulfide, 2-Component Urethane, Nylon, Delrin®,
Celcon®, High Nitrile Rubber (Buna N. NBR more than 36% Acrylonitrile),
Polyurethane, Polyethylene, Epichlorohydrin, Polyacrylate, Melamine,
Polypropylene, Baked Phenolics, Epoxy, Modified Alkyds
(® indicates trademark of DuPont Corporation)
Not Recommended:
Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish,
Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile Rubber
(Buna N. NBR less than 36% Acrylonitrile), EPDM, Ethylene Vinyl Acetate,
Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene Acrylonitrile (San), Butyl
GENERAL REQUIREMENTS - The piping, fittings, receiver tank, etc.
must be certified safe for at least the maximum working pressure of
the unit. Use hard-welded or threaded steel or copper pipes, cast
iron fittings and hoses that are certified safe for the unit's discharge
pressure and temperature. DO NOT USE PVC PLASTIC. Use pipe
thread sealant on all threads, and make up joints tightly to prevent
air leaks.
CONDENSATE DISCHARGE PIPING - If installing a condensate
discharge line, the piping must be at least one size larger than the
connection, as short and direct as possible, secured tightly and
routed to a suitable drain point. Condensate must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE: All compressed air systems generate condensate which
accumulates in any drain point (e.g. tanks, filters, drip legs,
aftercoolers, dryers). This condensate contains lubricating oil and/
or substances which may be regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
EN-4
CAUTION
WARNING
CAUTION
„ ELECTRICAL WIRING & GROUNDING
Any electrical installation and service required should be
performed by a qualified electrician who is familiar with all
applicable local, state and federal laws and regulations.
GENERAL - The motor rating, as shown on the motor nameplate,
and the power supply must have compatible voltage, phase and
hertz characteristics.
FUSES - . Refer to the National Electric Code to determine the
proper fuse or circuit breaker rating required. When selecting fuses,
remember the momentary starting current of an electric motor is
greater than its full load current. Time-delay or "slow-blow" fuses are
recommended.
GROUNDING - The unit is equipped with a power cord having a
grounding wire an an appropriate grounding plug. The plug must
be used with an outlet that has been installed and grounded in
accordance with all local codes and ordinances. The outlet must have
the same configuration as the plug. DO NOT USE AN ADAPTER.
In the event of a short circuit, grounding reduces the risk of
shock by providing an escape for the electric current. The unit
must be properly grounded.
Improper installation of the grounding plug can result in a
risk of electric shock. If repair or replacement of the cord or
plug is necessary, do not connect the grounding wire to either
flat blade terminal. The wire with insulation having an outer
surface that is green with or without yellow stripes is the
grounding wire.
Check with a qualified electrician or serviceman if the grounding
instructions are not completely understood, or if in doubt as to
whether the product is properly grounded. Do not modify the plug
provided; if it will not fit the outlet, have the proper outlet installed
by a qualified electrician.
This product is for use on a nominal 120-volt circuit and has a
grounding plug that looks like the plug illustrated below. Make sure
the product is connected to an outlet having the same configuration
as the plug. No adapter should be used with this product.
WARNING
WARNING
DANGER
A=Ground
B=Grounding Pin
C=Outlet
80444425 Rev. D

Publicidad

loading

Este manual también es adecuado para:

P1.5iu-a9-h