No.
Terminal
1
1
J
2
E
3
F
4
G
5
G / H
6
I / H
7
I
8
K
9
F / I
10
P
4.6.2 Pulse generator and external safety devices
In situations of increased requirements in terms of personal protec-
tion, we recommend, in addition to the internal power limitation of
the drive, the installation of a 2-wire photoelectric sensor. The in-
stallation of a 4-wire photoelectric sensor serves purely for the pro-
tection of property. For further information on our range of ac-
cessories, please refer to our sales literature or consult your spe-
cialist dealer.
NOTICE
Before using the drive for the first time, test it to make sure that it is
working properly and safely (see chapter Maintenance / Checks)
Description
Overview of terminal assignment at the drive head
Plug base for radio receiver
Connector for antenna. When using an external antenna, the shield must be
placed on the left adjacent terminal (F).
Connector for external pulse generator (accessories, e.g. key switch or code
keypad)
Connection for wicket door contact (accessory) or emergency stop. The drive
is stopped or the start-up is suppressed via this input. (see also chapter
Special settings, menu H: STOP-A settings)
Connection for photoelectric sensor LS2 (please refer to the connection
points of the photoelectric sensor manual for use of other photoelectric
sensors)
Connection for 4-wire photoelectric sensor (e.g. LS5). This input activates the
automatic reversal of the drive during closing.
Connection for e.g. 24 V signal light (accessory). Power supply 24 V DC,
max. 100 mA (switched)
Caution! Do not connect a push button!
Connection for external, protectively insulated lighting or signal lamp
(protection class II, max. 500 W) (accessory)
Power supply 24 V DC max. 100 mA (permanent)
Connection for Mobility Module (accessory)
EN - 57