Descargar Imprimir esta página

Novoferm N-423 Manual Del Usuario página 68

Ocultar thumbs Ver también para N-423:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.9.4 Menu 8: Door adjustments
NOTICE
After the setting was changed, the force learning cycle must be re-
peated.
1. Select menu item "8".
ð After approximately 2 seconds, the display flashes and the set value
appears. The factory setting is "4". Retain this setting. Modifications on the
soft run distances must only be carried out if expressly approved by the
door manufacturer.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
Value
0
1
2
3
4
5
6
7
8
9
Remarks:
These figures represent the soft run distances in cm measured at the carriage.
3. Press the programming button (PROG button) (D).
ð The display shows "9".
66 - EN
Start OPEN
Stop OPEN
0
0
15
0
0
15
15
15
25
30
15
15
15
15
35
35
55
15
Start CLOSE
0
15
0
15
25
15
15
65
15
soft run mode only
Stop CLOSE
0
0
40
35
40
55
15
45
100

Publicidad

loading