OPERATION
After you connected the effect to the mains, the DJ-LED CY-100 starts running. During the Reset, the motors
are trimmed and the device is ready for use afterwards.
Stand Alone operation
In the Stand Alone mode, the DJ-LED CY-100 can be used without controller. You can do without a
controller as the DJ-LED CY-100 features a built-in microphone, which provides automatic sound control.
Disconnect the DJ-LED CY-100 from the controller and select the desired "Master Mode".
Master/Slave-operation
Connect the master and slave-devices and adjust the settings as desribed above.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
Addressing
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the DJ-LED CY-100 will respond to the controller.
Please, be sure that you don't have any overlapping channels in order to control each DJ-LED CY-100
correctly and independently from any other fixture on the DMX data link.
If two, three or more DJ-LED CY-100 are addressed similarly, they will work similarly.
For address setting, press the Mode-button until the display shows „A.001" and set the desired address via
the Up/Down-buttons.
Controlling:
After having addressed all DJ-LED CY-100, you may now start operating these via your lighting controller.
Note:
After switching on, the DJ-LED CY-100 will automatically detect whether DMX 512 data is received or not. If
the data is received, the display will show "A.001" with the actually set address. If there is no data received
at the DMX-input, the display will show "A001".
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the DJ-LED
CY-100.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.