Descargar Imprimir esta página

Zodiac Z550iQ Guia De Inicio Rapido página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
WARNINGS
INSTALLATION AND MAINTENANCE
• Only a person qualified in the technical fields concerned (electricity, hydraulics or refrigeration) is authorized to
carry out any installation, maintenance or repair work on the appliance
• The appliance may not be installed close to combustible materials, or the air duct inlet of an adjacent building.
• When servicing the appliance, the composition and state of the heat transfer fluid must be checked, as well as
the absence of any traces of coolant.
• During the appliance's annual sealing test in accordance with applicable legislation, the high and low pressure
switches must be checked to ensure that they are securely fastened to the cooling circuit and that they cut off
the electrical circuit when tripped.
• During maintenance work, ensure there are no traces of corrosion or oil around the cooling components.
• Before beginning work on the cooling circuit, stop the appliance and wait for a few minutes before fitting the
temperature and pressure sensors. Some elements such as the compressor and piping may reach temperatures
in excess of 100°C and high pressures with the consequent risk of severe burns.
REFRIGERANT SPECIFICATIONS
Area check
• Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that
the risk of ignition is minimized.
Work procedure
• Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being
present while the work is being performed.
General work area
• AIl maintenance staff and others working in the local area shall be instructed on the nature of work being carried
out. Work in confined spaces shall be avoided.
Check for the presence of refrigerant
• The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician
is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is
suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Check for the presence of a fire extinguisher
• If any work involving heat is to be conducted on the refrigerating equipment or any associated parts, appropriate
fire extinguishing equipment shall be available to hand. Have a dry powder or CO2, fire extinguisher adjacent to the
charging area.
No source of ignition
• No person carrying out work in relation to a refrigerating system which involves exposing any pipe work shall use
any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing
and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place,
the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.
''No Smoking'' signs shall be displayed.
Area ventilation
• Prior to penetrating the unit in any way to perform any required service, ensure that the area is open and adequately
ventilated. Proper ventilation, to allow for safe dispersion of any refrigerant which may be inadvertently released to
the atmosphere, should be maintained while service is being performed on the unit.
PRODUCT INFORMATION FOR PRODUCTS WITH CONNECTIVITY (Under RED Directive)
Declaration of conformity
Hereby, Zodiac declares that the radio equipment type Z550iQ is in compliance with Directive 2014/53/EU. The
full text of the EU Declaration of conformity is available at the following address: https://www.zodiac-poolcare.
com/.
16

Publicidad

loading