Electric supply connections
• Cut the electricity supply before any work inside the appliance (risk of electric shock).
• Only a qualified and experienced technician is authorised to carry out cabling work within the
appliance or to replace the power cord.
• Make sure that the terminal screws are fully tightened (risk of fire). Incorrectly tightened terminal
screws will cancel the warranty.
• Do not disconnect the electricity supply when the appliance is running. If the electric power supply is
interrupted, wait a minute before restoring the power.
Connect the power cable
2 vis
Information: three-phase model terminal boards
• On three phase models, there is no live order to be respected.
Power supply
Max current
Minimum cable section
(H07RN-F type) *
Thermal magnetic
protection
(C or D curve)
18
MD4
MD5
220 - 240 V
1 N~
50-60 Hz
A
9
mm²
3G 2,5
3G 2,5
mA
*Cable cross section suitable for max.
lenght 20 meters.
The option connections (heating priority
and remote on/off) are made on the smaller
terminal block. The cables must pass
through the secondary cable gland. See the
manual for more information.
TD5
380 - 400 V
220 - 240 V
3 N~
50-60 Hz
50-60 Hz
11
4
5G 2,5
30
Power supply connection
Power supply
AC 380-400V
3 phase 50Hz
(TD5, TD8)
Power supply
AC 220-240V
1 phase 50Hz
(MD4, MD5, MD8)
delayed fuse
Heating priority connection
4
3
2
1
MD8
TD8
380 - 400 V
1 N~
3 N~
50-60 Hz
17,8
6,1
5G 6
5G 2,5
Remote "ON/OFF" connection
4 3 2 1
❶ Installation
L1
L2
L3
N
L
N
14
1
13
2
1 -
2 power
for flitration pump
power contractor coil
filtration timer
power contractor
(tripolar or bipolar)
for filtration system
pump motor
separate cable for
the "heating priority"
function (not sup-
plied)
heat pump termi-
nal board
fuse
: heat pump
terminal board
: remote "on/
off" switch (not
supplied)
: separate
connection cable
(not supplied)