Descargar Imprimir esta página

Electrolux EOM3H00X Manual De Instrucciones página 5

Ocultar thumbs Ver también para EOM3H00X:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Cabinet minimum height
(Cabinet under the worktop
minimum height)
Cabinet width
Cabinet depth
Height of the front of the
appliance
Height of the back of the
appliance
Width of the front of the ap‐
pliance
Width of the back of the ap‐
pliance
Depth of the appliance
Built in depth of the appli‐
ance
Depth with open door
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
• All electrical connections should be made
by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to the
mains plug and to the mains cable. Should
the mains cable need to be replaced, this
must be carried out by our Authorised
Service Centre.
• Do not let mains cables touch or come
580 (600) mm
• The shock protection of live and insulated
560 mm
550 (550) mm
• Connect the mains plug to the mains
589 mm
571 mm
• If the mains socket is loose, do not
595 mm
• Do not pull the mains cable to disconnect
559 mm
• Use only correct isolation devices: line
569 mm
548 mm
• The electrical installation must have an
1022 mm
560x20 mm
• This appliance is supplied only with a main
1500 mm
4x25 mm
For the section of the cable refer to the total
power on the rating plate. You can also refer
to the table:
The earth cord (green / yellow cable) must be
2 cm longer than the brown phase and blue
neutral cables.
near the appliance door or the niche below
the appliance, especially when it operates
or the door is hot.
parts must be fastened in such a way that
it cannot be removed without tools.
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
connect the mains plug.
the appliance. Always pull the mains plug.
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
isolation device which lets you disconnect
the appliance from the mains at all poles.
The isolation device must have a contact
opening width of minimum 3 mm.
cable.
Cable types applicable for installation or re‐
placement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
Total power (W)
maximum 1380
maximum 2300
maximum 3680
Section of the cable
(mm²)
3x0.75
3x1
3x1.5
ENGLISH
5

Publicidad

loading