Turn off water supply before starting.
Installation must comply with all state and local laws and regulations.
1
INSTALLING FILTRATION SYSTEM
a
Personal Injury: Do not locate filter above an
outlet or other electrical device. Install head and bracket
so that connections require no stretching, kinking or
pinching of tubing.
b
From water
supply line
NOTICE
Property Damage: Tube runs need to form to the
cabinet's contours to allow storage space with no sharp
bends. Tubes need clean, perpendicular,
burr-free cuts to ensure a true fit.
c
HC1100, HC2200,
HC2215
From filter or
water supply line
NOTICE
Property Damage: Do not extend the lines farther
than the 16" provided. Ensure tube(s) and "Y"
connnector are securely fit.
d
From water
supply line
It is normal for approximately 2 oz. of water
to discharge when filter is removed.
4
44688_RevE_2023_04_26.indd 5
44688_RevE_2023_04_26.indd 5
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
To dispenser
C1100, GN1100, GN2200,
GN2215, HC3300, H3300
Plug
From filter or
water supply line
To dispenser
Separate cartridge from filter head.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" starter holes and attach bracket
to wall with wood screws, turning until snug.
Insert cartridge into filter head. Top
surface of cartridge will become flush with
bottom of filter head when fully engaged.
Determine length of tubing required,
then cut to length making sure the cut
is perpendicular and burr-free.
Insert a white 1/4" tube into inlet side
of filter head until it stops. Press in
again to ensure a secure fit.
Insert the other white 1/4" tube into
outlet side of filter head until it stops.
Press in again to ensure a secure fit.
Insert the copper tubes(s) from the
dispenser into "Y" quick-connector
using the plug for hot-only models.
Connect the white 1/4" tube from
the right outlet on the filter head into
the quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
Connect remaining white 1/4" tube to
incoming water supply line.
2