Electrical Connections - Erreka AR24C Manual Del Instalador

Accionador electromecánico para puertas batientes
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5

ELECTRICAL CONNECTIONS

A- AR24C with 24Vdc control panel with limit switch (VIVO-D203)
A2
A1
B- AR220C with 230Vac control panel without encoder (VIVO-M201)
A2
A1
C
Capacitor
FC1 Limit switch 1
FC2 Limit switch 2
M
Motor
1 Complete the connections as shown in the figure:
1 Grey cable: common limit switches (FC1 and FC2)
2 Brown cable: limit switch 1 (FC1)
3 Black cable: limit switch 2 (FC2)
4 Blue/black cable: motor (24Vdc)
5 Red cable: motor (24Vdc)
2 Use ST1 (open), ST2 (close) to check the correct
operation of the actuator (parameter C1 for A1, C2
for A2).
Check the instructions for the control panel in
order to install the other electrical components.
3 Adjust the travel using the ends of travel of the
actuator (see "Adjust the ends of travel" on
page 20).
P64Xb
1 Complete the connections as shown in the figure:
1 Yellow/green cable: earth
2 Brown cable: turn 1
3 Grey cable: common
4 Black cable: turn 2
2 Use PUL1 (close), PUL2 (open) to check the correct
operation of the actuator.
Check the instructions for the control panel in
order to install the other electrical components.
3 Adjust the travel using the ends of travel of the
actuator (see "Adjust the ends of travel" on
page 20).
P64Yb
INSTALLATION
ARC electro-mechanical actuator
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ar220c

Tabla de contenido