• Incubation humid (default 47)
Speed fan regulation (ref. mod. MG 140/200 rural)
Press the "Fan" key to enter the fan speed set up page, choose the set value 1,2 or 3 by the keys
pressing again the key "Fan".
Speed 1 = lower fan speed suggested for breeding live animals in the first week of life.
Speed 2 = medium fan speed suggested for hatching period (last 2 days)
Speed 3 = maximum speed suggested during incubation period
Technical menu
Pressing simultaneously both keys
To view a set value press the " SET key and, if required, change it by using the keys
The electronic instrument will automatically exit the programming menu if no keys are pressed for longer than 25 Sec.
Technical menu parameters list
• Unit Misura temp
[°C,°F] (default °C)
• Inc. temp. min.
[5,0 .. 75,0] (default 25.0) Used to limit the minimum acceptable temperature value in the "incuba-
• Ist. temp. inc. /
[0,1 .. 5,0] (default 0.1)
Inc. temp. hyst.
• Inc. temp. max.
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable temperature value in the "incuba-
• Alarm temp. min.
[5,0 .. 75,0] (default 30.0) Used to limit the minimum acceptable value in the parameter "alarm
• Alarm temp. max.
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable value in the parameter "alarm
• Alarm temp.hyst.
[0,1 .. 5,0] (default 0.1)
• Calib temp.probe
[-5,0 .. +5,0] (default 0.0) Used to calibrate the temperature value detected by the probe
• Humidity minimum [10 .. 90] (default 40)
• Humidity maximum [10 .. 99] (default 65)
• Humidity hyst.
[1 .. 20] (default 1)
• Cal.humid. probe
[-30 .. +30] (default 0)
• Language
[0 .. 1] (default 0)
• Default parameter VENT. to reset Setting of default parameters/Pressing the FAN button all default parameters are set
• Type of fan
[1 .. 4] (default 1)
• Buzzer Mode
[0 .. 2] (default 2)
0 = Buzzer off
1 = Buzzer on for pressing the keys
2 = Buzzer on when pressing keys and in case of high temperature alarm
LCD THERMOSTAT INCUBATION CALENDARY
Once one or more hatching cycles calendars are activated, the display will show, further than temperature and humidity
values, the counting of the total number of days & hours spent from the begin of the first hatching cycle.
Ciclo: Z ---d --h
SET=Inizio Ciclo (Z = number of the visualized cycle)
If the cycle is activated
By repeatedly pressing the 'P' button you will run through the 4 incubation cycles. Pressing the 'SET' button you can start
or stop the cycle of incubation displayed. It will be possible to "force" the display of a particular cycle, including those
active on the working screen (so not only the cycle started by longer) by pressing the' P ' key until you reach the cycle to
be displayed, and letting the tool go to time-out (about 30 Sec).
16
The range of values that can to be setted in this scale is definited by the parameters
"Temp.alarm.min." e "Temp.alarm.max." showed in the technical menu.
This parameter allows to set the relative humidity to be maintained during incubation
period. The range of setting values in this scale is definited by the parameters "Min.
Humidity" and "Max.humidity" showed in the technical menu.
+
, you will access the "Technical menu".
Celsius / Fahrenheit degrees instrument setting
tion parameter" on the User Menu
Used to set up hysteresis (accuracy) of working temperature
tion" parameter" on the User Menu
temperature" on the User Menu
temperature" on the User Menu
Used to set up with the maximum accuracy the alarm temperature hyste-
resis
Used to limit the minimum acceptable value in the parameter "incubation
humidity" on the User Menu
Used to limit the maximum acceptable value in the parameter "incuba-
tion humidity" on the User Menu
Used to set up with the maximum accuracy the humidity regulation
hysteresis
Used to calibrate the humidity value detected by the probe
Used to select the languages shown on the display (Italian / English)
Used to set up the fan motor type controlled by the instrument
Used to set up the buzzer operating mode.
Pressing the "P" button you will accede to the hatching cycles programming
menu. The display will show different indications according to the state of
the running incubation cycle. If the cycle is not activated
Ciclo:Z XXXd YYh
SET= Fine Ciclo_
Fan motor type
1
MG50-MG70-MG100-MG140
2
3
MG500-432-576-720-MG400H
and
and confirm
and memorize by "set".
and
Incubator model
MG244