Technical Data - DITEC NRG90TXE Manual Tecnico

Automatizaciones para puertas seccionales industriales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

3. TECHNICAL DATA

Power Supply
Frequency
Power
Amperage
Torque
Output Speed
Hollow shaft
Max. door weight
Holding torque
Motion management
Working temperature *
Max cycles per hour
Limit switch range
(Motor shaft round)
Protection rate
Unlocking drive
Control panel
i
* In the range -10°C and +40°C the nominal values are respected. In case of temperature higher/lower performance may
dropped.
EN
Ditec NRG90TRE
400V~
50Hz
0,80kW
2,20A
90Nm
21rpm
25,4mm (1")
400kg
450Nm
Absolute encoder
-20°C ÷ +60°C
20
18
IP54
Fast-realese lever
EL500E
283
25,4
385**
545,5***
Flange bracket
20
Ditec NRG90TXE
400V~
50Hz
0,80kW
2,20A
90Nm
21rpm
25,4mm (1")
400kg
450Nm
Absolute encoder
-20°C ÷ +60°C
20
18
IP54
Chain
EL500E
45
45
66
187
- ** Ditec NRG90TRE
- *** Ditec NRG90TXE, NRG90TXF and NRG140TXE
90
135
22,5
10
20
20
10
Ditec NRG90TXF
Ditec NRG140TXE
400V~
50Hz
0,80kW
0,87kW
2,20A
90Nm
140Nm
21rpm
25,4mm (1")
25,4mm (1")
400kg
450Nm
500Nm
Mechanical limit
Absolute encoder
switches cams
-20°C ÷ +60°C
-20°C ÷ +60°C
20
18
IP54
Chain
EL400/EL500E
EL500E
110
50
400V~
50Hz
2,30A
18rpm
650kg
20
18
IP54
Chain

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nrg90treNrg90txfNrg140txe

Tabla de contenido