Follow the safety instructions for fuel control. Filter the fuel before refuelling to prevent
foreign particles from entering the combustion chamber. Wipe up spilled fuel.
13.3.3
Check hydraulic oil
In the hydraulic oil tank must be approximately 3,5 liters of hydraulic oil (HL 46 or similar).
13.4
Operation
13.4.1
Start Engine
Start the engine, if you have your wheeled dumper mounted correctly:
Set the gear selection lever (7) to the neutral position.
Move the choke lever on the machine to the full choke position.
Turn engine switch to "ON".
Pull the starter rope several times so that the carburettor is filled with gasoline.
Pull the starter handle, pull-out until resistance is felt. Let the rope rewind slowly across and
then move expeditiously.
Run the pull-starter handle slowly to the rope guide back as soon as the engine starts.
Set the choke lever after a few seconds of engine run position ˝OPEN˝
To start the engine is warm the choke lever is not to be operated.
When the engine is warmed up, place the gear lever (7) (forward / reverse) in the desired
position. If the desired gear cannot load, press the clutch lever short and repeat the process.
After inserting the gear lever Push the clutch lever and the mini transporter begins to drive.
Drag to adjust the throttle lever to the speed accordingly.
With the steering arm on the handles and can be easily controlled. To drive in the desired
direction each use the right or left steering lever.
13.4.2
Idle speed
Throttle lever to the "SLOW" (SLOWLY) take to protect the motor if no work is done.
Downshifting the engine to idle prolongs the life of engine reduces fuel consumption and the noise
level of the machine.
13.4.3
Stop the engine
To stop the engine, release the clutch lever and turn the switch on the motor to the "OFF" position.
Under normal conditions, proceed as follows.
ZIPPER MASCHINEN GmbH
www.zipper-maschinen.at
N O TE
1.
Refuelling only outdoors!
2. Before removing the fuel tank cap, turn the motor off and
let the machine cool down.
3. Clean the fuel tank cap area.
4. Remove the fuel tank cap carefully.
5. Visual check of the filling level.
6. If necessary, refill with fuel.
7. Fuel tank capacity: see technical data. Fill tank only up to
1.5 cm below the rim of the filler neck, so that the fuel has
place for expansion.
NOTE:
use fuel with the appropriate octane number (RON
95).
8. Replace and tighten the fuel tank cap.
9. Wipe any fuel residues and wait until it evaporates.
OPERATION