MAINTENANCE
Troubleshooting
Troubleshooting
Problem
Pump does not turn on
Pump will not shut off Liquid inflow matches pump capacity
Pump runs but does
not discharge liquid
Pump does not deliver
rated capacity
Replacement Parts
Part Number
305624001
305624002
For technical assistance, parts, or repair, please contact:
800.701.7894 | littlegiant.com
10000005491 Rev. 003 02/22
Probable Causes
Pump not connected to electrical power
Circuit breaker off or fuse removed
Defective motor
Lift too high for pump
Inlet to impeller plugged
Lift too high for pump
Low voltage, speed too slow
Impeller or discharge pipe is clogged
Impeller wear due to abrasives
Bottom Screen Kit
Parts Kit: screw, impeller, nut, seal, volute, & screen
Corrective Action
Connect pump to a dedicated circuit
equipped with GFCI.
Turn on circuit breaker or replace fuse.
Replace pump.
Larger pump required.
Check rated pump performance.
Pull pump and clean.
Check rated pump performance.
Check that supply voltage matches the
nameplate rating.
Pull pump and clean. Check pipe for
scale or corrosion.
Replace pump.
Description
Franklin Electric Co., Inc. | Oklahoma City, OK 73157-2010
Copyright © 2022, Franklin Electric, Co., Inc. All rights reserved.