5 Control (325-500)
5.1 Control panel
UP button: press to increase the value of a selected editable parameter.
PRESSED FOR 3s START MANUAL CONDENSATE DRAIN
DOWN button: press to decrease the value of a selected editable parameter.
esc
ESC button : to exit without saving; returns to the previous level;
PRESSED FOR 5s. ALARM RESET.
set
SET button : to exit and saving/ confi rm the value; go to the next level; enter on Set Menu;
PRESSED FOR 5s. START DRYER.
esc set
: press together at the same time to enter on the parameters of the program.
5.2 Symbol
Symbol Symbol status Function
Lit up
compressor ON
k
Off
compressor OFF
Lit up
dryer ON
Flashing
dryer OFF
Lit up
Alarm present
!
Flashing
Warning present
Off
No alarm present
q
Lit up
Condensate drain ON
Off
Condensate drain OFF
English
Symbol Symbol status Function
Dryer ON
illuminated
Compressor OFF
illuminated
Maintenance
illuminated
°C
grade
°F
illuminated
Bar
pressure
PSI
PSE 325-1000 60Hz
5.3 Parameter settings
Temperature measurement unit
How to set the temperature measurement unit.
set
esc
1. Press
and
together at the same time to enter general menu "PAr" .
set
to fi nd menu " CF9" .
2. Press
set
3. Press
to enter .
to fi nd the menu " A1".
4. Use the arrows
or
set
5. Press
to choose: ON = Fahrenheit (PSI) / OFF = Celsius(bar).
set
6. Press
to confi rm.
esc
7. Press
to exit.
esc
set
PAr
set
esc
CF9
set
esc
---
A1
set
esc
On
OFF