• An optional cable with a diameter of 4.0 mm - 5.5 mm should be routed through a
separate cable gland. See Product overview on page 12.
1. Use the supplied drill template to prepare a wall or pole for installation of the wall
bracket.
2. Route the network cable through the wall bracket, and through the bracket adapter.
Leave approximately 30 cm (11.8") of cable for connecting to the camera.
3. Install the wall bracket on a wall, ceiling, or pole using screws and plugs appropriate for
the material (e.g. wood, metal, sheet rock, stone).
Do the following to route the network and other (optional) cables:
1. Loosen the bottom cover screws and lift the top cover.
2. Loosen the cable cover screws; detach the cable cover from the bottom cover.
3. Remove the cap, the plug and the gasket from the cable gland to be used.
4. Remove the grounding screw, washer and grounding shoe ring.
5. Fasten the shoe ring mounted grounding wire and washer with the grounding screw.