properly and no components
show wear and tear.
Warning! This product is a
PV-module with integrated
electronics. Changes and
replacement of any part shall
only be performed according
manufacturer' s instruction to
avoid hazards.
The inverter is a non-
removable product. If you
have any problems, please
contact after-sales service.
Warning! When the
photovoltaic array is exposed
to light, it supplies a d.c.
voltage to the PCE.
The isolation transformer
between PV and AC inside
the inverter meets the
requirements of strengthened
insulation.
Installation
Suitable Balconies
Before unpacking, please verify that
your balcony is compatible with the
included mounting system:
The hand rail itself and its connection to the
building is capable and approved to carry
the added weight. This must include the
wind force.
Please check the technical specifications
for the maximum suitable wind zone, and
verify the local wind zone with your local
authorities to verify.
The hand rail is round, within a diameter
of 45 mm. The banister has vertical or
horizontal struts, round, with a diameter
within 20 mm.
The mounting system is only suitable for
installing the panel parallel to the banister
itself; no added inclination is allowed.Check
your state building code for requirements for
the erection of installations. The static system
calculation shoudl allow installations up to 7
m above ground.
If the circuit breaker is added at the
AC side, the circuit breaker with the
rated current of 10A is recommended.
Required Tools
A. Torx T27 & T45 Key
B.
10 mm & 13 mm spanner
wrench
Step 1: Decide installation position
The solar panel is suitable for vertical
B
and horizontal mounting. The
orientation has no influence on power
production. You only need to consider
the available space and the desired
location of the inverter.
If you wish to connect a second panel
C
(sold separately) to the same inverter,
please mind the limited length of
the connector cables. Choose an
orientation and inverter position that
allows rinning the cables tension-free.
Choose an inverter position within
23