Nivel de láser giratorio de doble pendiente m18

Publicidad

Idiomas disponibles

Idiomas disponibles

SYMBOLOGY
ASSEMBLY
Recharge only with the charger
WARNING
specified for the battery. For spe-
cific charging instructions, read the operator's
manual supplied with your charger and battery.
Removing/Inserting the Battery
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
Always remove the battery pack
WARNING
any time the tool is not in use.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
Volts
Direct Current
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
Read Operator's Manual
Power Button
Menu Button
Grade Button
Leveling Button
D-Pad
X-Axis Indicator
Y-Axis Indicator
Coin Cell Polarity Indicator
Lock
Unlock
Only use accessories specifically
WARNING
recommended for this tool. Others
may be hazardous.
To reduce the risk of injury or damage, securely
mount/attach the laser before starting an opera-
tion. Injury/damage may occur if the laser falls.
Mounting the Rotary Laser
The rotary laser can be mounted to a
tripod or rotary laser wall mount:
• If working overhead, ensure the
laser is secure before operating
and attached to a MILWAUKEE
35 lbs rated lanyard.
• Ensure the laser and accessories
are on a stable surface.
• Use one of the 5/8"-11 threaded inserts to mount on
a tripod or MILWAUKEE Rotary Laser Wall Mount.
Lanyard Attachments
Use MILWAUKEE Lanyards to
help reduce the risks associated
with dropped tools. Complies
with ANSI/ISEA 121:2018.
1. Follow instructions provided
with tool lanyard.
2. When using the lanyard,
user must attach both short
handles together properly, as shown above, before
operation.
WARNING! To reduce the risk of serious injury or
death, use only lanyards rated for the weight of
the tool.
Laser Orientation
The rotary laser can operate in horizontal and
vertical plane orientations. When in auto-leveling
mode, the laser will adjust to create a level or
plumb plane, respectively. When placed in vertical
orientation, the laser will default to a plumb point
mode for setup. To project a vertical line, press
the menu button, and then select the RPM icon.
Choose the desired RPM then press the "OK" button.
NOTE: The laser will only work in one specific vertical
orientation, with the keypad facing up and parallel to
the working surface. Other orientations will result in
a leveling error.
Horizontal Orientation
5
Vertical Orientation

Publicidad