PERFORMANCE
Model
SPA02501VDK/SPA02501TDK
SPA03301VDK/SPA03301TDK
SPA05001VDK/SPA05001TDK
SPI05004VDK/SPI05004TDK
SPI07504VDK/SPI07504TDK
SPI10004VDK/SPI10004TDK
SPS03301VDK/SPS03301TDK
SPS05001VDK/SPS05001TDK
SPS07501VDK/SPS07501TDK
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion
or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnect the power.
5.
Release all pressure and drain all water from the system before servicing any component.
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
8.
Wear safety goggles at all times when working with pumps.
9.
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor
cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must
be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this
pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI
outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should
be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping
the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature
failure.
2
GPH of Water @ Total Feet Of Lift
HP
0 ft.
5 ft.
1/4
3450
3200
1/3
3600
3400
1/2
4100
3800
1/2
4600
4320
3/4
5150
4800
1
5500
5160
1/3
4000
3700
1/2
4200
4000
1
5100
4800
10 ft.
15 ft.
20 ft.
2800
2100
1500
3000
2500
1900
3500
2900
2300
3840
3060
1800
4320
3660
2580
4680
4200
3480
3300
2800
1860
3600
3200
2400
4500
4000
3300
For Professional Technical Support call 1-844-242-2475
Max.
Lift
25 ft.
200
26 ft.
1000
28 ft.
1600
29 ft.
-
22 ft.
-
25 ft.
2340
30 ft.
-
25 ft.
1200
29 ft.
2400
32 ft.