4. Install discharge plumbing. Insert rigid plastic pipe into the slip of male adapter,. Screw pipe into the pump hand tight
plus 1-1/2 turns.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used,
make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump
movement, switch interference and prevent the pump from starting or stopping.
5. To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. (47.6 mm) I.D., e.g. radiator hose) can
be connected into the discharge line near the pump using suitable clamps.
6. Install an in-line check valve or an in-pump check valve to prevent flow backwards through the pump when the pump
shuts off.
NOTE: If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8"(3.2mm)
hole in discharge pipe about 1"-2"(2.5 -5.1cm) above connector. The hole must be in the sump.
7. Power Supply: Pump is designed for 115 V, 60 Hz, operation and requires a minimum 15 amp individual branch
circuit. Plug the power plug into a 115V GFCI power outlet.
WARNING: Risk of electric shock. Can shock, burn or kill. Pump should always be electrically grounded to a
suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire
system. Do not cut off the round ground pin.
8. If the pump discharge line is exposed to outside subfreezing atmosphere, a portion of line exposed must be installed
so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause water trapped in the
discharge to freeze which could result in damage to the pump.
9. After the piping and check valve have been installed, the unit is ready for operation.
10. Check the pump operation by filling the sump with water and observing pump operation through one complete cycle.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. Failure to make this operational
check may lead to improper operation, premature failure, and flooding.
OPERATION
WARNING: Risk of electric shock. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water.
1. The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water as the seal
may be damaged if allowed to run dry.
2. The motor is equipped with an automatic reset thermal protector. If temperature in the motor should rise unduly, the
switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the
switch will reset automatically and restart the motor. If the protector trips repeatedly, the pump should be removed
and checked. Low voltage, long extension cords, clogged impeller, very low head or lift, or a plugged or frozen
discharge pipe, etc., could cause the protector to trip.
3. The pump will not remove all water. If operating a pump manually, and suddenly no water comes out of the discharge
hose, shut off the unit immediately. The water level is probably very low and the unit has broken prime.
WARNING: Risk of electric shock. Can shock, burn or kill. Before attempting to check why the unit has stopped
operating, disconnect power from the unit.
CAUTION: Do Not Change the preset tether length.
For Professional Technical Support call 1-844-242-2475