Descargar Imprimir esta página

Kärcher Chariot CV 60/1 RS Manual Del Usuario página 51

Ocultar thumbs Ver también para Chariot CV 60/1 RS:

Publicidad

Idiomas disponibles

Idiomas disponibles

Code
Description of Code
Drive Motor Unknown Motor Controller
17
18
Brake Detect Error
Drive Motor External Temperature
19
Sensor Error
1A
Drive Motor Open Circuit
1B
Drive Motor Overheat
1C
Vacuum Motor Short
1D
Vacuum Motor Low FET Error
1E
Vacuum Motor High FET Error
Vacuum Motor Internal Motor
1F
Controller Error
Vacuum Motor Unknown Motor
20
Controller Error
21
Vacuum Motor Overcurrent Error
22
Vacuum Motor Open Circuit
23
Clogged Hose, Hopper, or Bag
24
Actuator Overcurrent
25
Traction Motor DMC Over Temperature
26
Brush Motor DMC Over Temperature
Side Broom Motor DMC Over
27
28
Vacuum Motor DMC Over Temperature
Error
Temperature
8.644-716.0 Manual Operator Chariot CV60/1 RS
Corrective Actions –
If the problem persists, call for service
Disconnect power with the main breaker, remove the brush
tray and clean the brushes.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Locate the traction motor circuit breaker and reset..
Allow the traction motor cool down for 1 hour before
continuing operation
Turn the main breaker off and wait 10 seconds before
turning it back on.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Disconnect power with the main breaker, remove the side
broom and clean.
Locate the side broom circuit breaker and reset.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Locate the vacuum motor circuit breaker and reset.
Change the vacuum bag.
Inspect the vacuum hose and hopper and clear any clogs.
Turn the main breaker off and wait 10 seconds before
turning it back on.
Disconnect power with the main breaker.
Remove the side broom and clean.
Remove the brush tray and clean the brushes.
Allow the controllers to cool down for 1 hour before
continuing operation.
Disconnect power with the main breaker.
Remove the side broom and clean.
Remove the brush tray and clean the brushes.
Allow the controllers to cool down for 1 hour before
continuing operation.
Disconnect power with the main breaker.
Remove the side broom and clean.
Remove the brush tray and clean the brushes.
Allow the controllers to cool down for 1 hour before
continuing operation.
Disconnect power with the main breaker.
Remove the side broom and clean.
Remove the brush tray and clean the brushes.
Allow the controllers to cool down for 1 hour before
continuing operation.