Error condition list.
If occurs, try to turn Off the machine, wait for a few
seconds, then turn ON again. If the error remains, a
maintenance is required.
technical service center or Lincoln Electric and report the
LED Status found on the machine Front Panel.
On
This occurs if after 4seconds the Pilot Arc
isn't transfered to the workpiece.
machine stops the pilot arc to avoid
overheating on the Torch Head.
Head Torch
To restore the machine:
Release
pushbutton. The blinking LEDs are
now permanently ON
Press again the release the Torch
Trigger pushbutton.
On
The Torch Trigger pushbutton is pressed.
During this period the machine try to start
the pilot arc for 4 times. If the pilot arc
doesn't start the machine automatically
goes in a safe condition that allow to
check as necessary.
No pilot arc
estabilished
To restore the machine:
Turn OFF the Power switch.
Check the correct placement of the
Torch Head consumables and parts.
Check
connections.
Turn ON again the machine.
On
This occurs if the machine is switched
ON (or if it restart after cooling time) with
the Torch Trigger pushbutton hold. This
status
conditions:
processes must be started ONLY under
the direct control of the operator.
Trigger
To restore the machine:
Pushed
Release
pushbutton.
Press
pushbutton.
If this error condition persist check for
eventual malfunctions of the the Torch
Trigger pushbutton.
English
Please contact the nearest
Blink
Blink
the
Torch
Trigger
On
On
the
Torch
electrical
On
On
On
avoids
unsafe
operating
manual cutting or gouging
the
Torch
Trigger
again
the
Torch
Trigger
Rear Panel Controls and Connections
A. Fan:
This machine
has a F.A.N. (Fan As
Needed)
inside:
the fan is
automatically
ON or OFF.
feature reduces the
amount of dirt which
can be drawn inside
the
machine
reduces
The
consumption.
the machine is turned
ON the fan will turn
ON.
The fan will
continue
whenever the torch trigger pushbutton is pressed. If
the torch trigger pushbutton is released for more than
five minutes, the fan will turn OFF.
B. Power Switch: It turns ON / OFF the input power to
the machine.
C. Input cable: Connect it to the mains.
D. Gas Inlet: Connect here the hose carrying the gas to
the machine.
A clean, dry primary gas (air or nitrogen) must be
supplied to the machine. A pressure setting above
7,5bar could damage the torch. Failure to observe
these precautions could result in excessive operating
temperatures or damage to the torch.